1 System One Heated Humidifier USER MANUAL 2 2009 Respironics Inc. And its affiliates. All rights reserved. 3 Table of Contents Intended Use. 2 Symbol Key. 2 System Features and Contents.3 Connecting the Therapy Device.4 Disconnecting the Therapy Device.5 Daily Use. 5 Home Cleaning: Water Tank.9 Home Cleaning: Humidifier Base.9 Hospital and Institution Cleaning.10 Service.10 Traveling with the System.10 Troubleshooting.11 Specifications.13 Disposal.14 How to Contact Respironics.14 EMC Information.15 Limited Warranty.Back Page 1 4 Caution: U. Read Online >> Read Online Conchatherm neptune operators manual. Concha column hudson rci humidifier teleflex high flow nasal cannula. The Hudson RCIĀ® NeptuneĀ® Heated Humidifier with ConchaSmartĀ® Technology includes best-in-class features, such as low water notification and an. Federal law restricts this device to sale by or on the order of a physician. Intended Use The Heated Humidifier is an accessory for the Respironics REMstar and BiPAP therapy devices to provide moisture to the patient circuit. It is intended for use in spontaneously breathing patients weighing over 30 kg (66 lbs), in the home or hospital/institutional environment, who use mask-applied positive pressure ventilation therapy. Warnings A warning indicates the possibility for injury to the user or the operator. Use the humidifier only for its intended use as described in this manual. Use only accessories recommended by Respironics. Periodically inspect the humidifier for signs of wear or damage. Never operate the humidifier if any parts are damaged, if it is not working properly, or if the humidifier has been dropped or mishandled. Download film kartun anak upin dan ipin. Do not use the humidifier if the water tank is leaking or damaged in any way. Have any damaged parts replaced before continuing use. Periodically inspect the humidifier power cord for signs of wear or damage. If it becomes worn or damaged, contact Respironics or your home care provider for a replacement. Allow the humidifier heater plate and water to cool down for approximately 15 minutes before removing the water tank. A burn may result from: touching the heater plate, coming in contact with the heated water, or touching the tank pan. This equipment is not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. When installing the water tank, do not allow any water to spill into the humidifier or therapy device. If you notice any unexplained changes in the performance of this device, if it is making unusual or harsh sounds, if it has been dropped or mishandled, if water is spilled into the enclosure, or if the enclosure is broken, disconnect the power cord from the therapy device and discontinue use. Contact your home care provider. Before cleaning the humidifier, always remove from the therapy device. Empty and clean the water tank daily to prevent mold and bacteria growth. Wipe the seal completely. Note: Please see the Limited Warranty section of this manual for information on warranty coverage. Cautions A caution indicates the possibility of damage to the device. Do not place the humidifier directly onto carpet, fabric, or other flammable materials. Do not place the device in or on any container that can collect or hold water. Take precautions to protect furniture from water damage. Do not fill the water tank above the maximum fill line. Damage to the humidifier or therapy device may occur. If the water tank is overfilled, water may leak out of the tank inlet (located on the back of the tank) when installing the tank lid. Use only room temperature distilled water in the tank. Do not put any chemicals or additives into the water. Possible airway irritation or damage to the water tank may result. Remove the tank, empty all water, and replace the empty tank before transporting the humidifier base.
0 Comments
Leave a Reply. |